30A135
ITEM
ACTION
RESPONSE
1
ENSURE
the drain valve on the fryer is in the
CLOSED
position, shortening is at the proper level, the
fryer
TOGGLE ON/OFF
switch is
ON
; then depress the
ON/OFF key on the Ultrastat 11 Cooking Computer.
A. The
AMBER
Power Lamp beside the Fryer Toggle ON/OFF
Switch will
LIGHT.
B.
CY P
will appear in the display indicating the computer is
in the
PURGE MELT MODE.
C. Each time the computer turns the heat mechanism
ON
a “dot”
will appear in front of
.
CY
P
and the red indicator lamp
besides the fryer
TOGGLE ON/OFF
switch will
LIGHT.
2
When shortening is heated depress the
EXIT MELT
key
on the computer.
A.
HEAt
will appear in the display indicating the computer is
in the
FULL ON
mode and has turned the
BURNER ON
until
SETPOINT
temperature is reached.
3
When
droP
appears in the display indicating short-
ening is at the SETPOINT temperature:
1- Drop the product to be cooked
2- Depress either the
1
%
or 2
&
key
to start the cook cycle.
A.
3.00
will appear in the display indicating the product cook
time and will immediately start counting
DOWN.
B. The lamp above
1
%
/ 2
&
will BLINK to indicate that
the timer is in use.
C. Each time the computer turns the burner
ON
, a “dot” will
appear before the time and the
RED
indicator lamp besides
the fryer
TOGGLE ON/OFF
switch will
LIGHT.
4
When the time displayed counts down to
0:00
the
alarm will be turned
ON
to alert the cook that the
cook cycyle is ended. At this time:
1 - Remove the product from the shortening
2 - Depress the
1
%
or 2
&
key to turn the alarm
OFF
and reset the timer.
A.
droP
will appear in the display to indicate that the timer is
ready for another cook cycle.
5
Repeat steps 2,3 and 4 to start additional cook cycles.
NOTES:
1 - To display the
ACTUAL
shortening temperature, depress the
TEMP
key
ONE
(1) time.
2 - To display the
SETPOINT
temperature, depress the
TEMP
key
TWO
(2) times.
3 - To display the
TIME
remaining in a cook cycle, depress the
TEMP
key
THREE
(3) times.
4 - Steps 1, 2, 3 and 4 will have to be repeated each time any of the following occurs:
DRAIN VALVE IS OPENED
FRYER TOGGLE ON/OFF SWITCH IS TURNED OFF TO FILTER SHORTENING OR BOILOUT A FRYER
FRYER TOGGLE ON/OFF SWITCH IS TURNED OFF AT CLOSING
NOTE:
For more detailed information on the Ultrastat 11 Cooking Computer including how to program the computer
refer to the Ultrastat 11 Cooking Computer Operating Instructinons PN 30A053 provided with the fryer.
F.
ULTRASTAT 11 COOKING COMPUTER OPERATION
NOTE:
Ultrastat 11 Cooking Computers will be prorammed by Ultrafryer Systems for cooking products at 350ºF (177ºC) for
3 minutes.
Page 36 of 61
Summary of Contents for PAR-3-HE
Page 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Page 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Page 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Page 18: ...30A135 INITIAL START UP Page 14 of 61...
Page 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Page 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Page 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Page 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Page 31: ...30A135 CLEANING Page 27 of 62...
Page 36: ...30A135 FRYER OPERATION Page 32 of 61...
Page 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Page 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Page 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Page 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Page 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Page 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Page 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Page 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Page 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...