G. AUTOMATIC SAFETY FEATURES:
1. High limit thermostat to shut off gas to the main burners by opening a solenoid-actuated safety
valve in the combination gas control valve.
2. Combination gas control valve which includes a built-in pressure regulator and manual valve.
3. Sensing circuit within the spark ignitor module to turn gas to the fryer OFF if a burner FLAME
OUT occurs.
4. A Drain Valve Safety Switch that will DISABLE the fryer each time the drain valve is OPENED.
5. An AIR PRESSURE switch to open the electrical circuit to the spark ignitor and gas valve which
will turn the gas to the fryer OFF in the event the blower fails.
H. EUROPEAN PRESSURE, GAS AND CATEGORIES TABLE