A. UNPACKING
Check that the container is upright and that the plastic wrap is securely strapped to the wooden skid. Check for visible dam
age; and if damage has occurred, do not refuse shipment, but contact the carrier and file the appropriate freight claims.
CAREFULLY remove the plastic wrap and straps; then remove the fryer from the skid.
B. INSTALLING
Roll the assembled fryer into the building, to it‟s operating location.
C. LEVELING
1. When the fryer is placed in its operating location check to be sure it is level. If not, loosen the casters and insert the appro-
priate number of shim plates between leg and caster plates then retighten the caster bolts.
2. If the floor is smooth and level, adjust to the high corner and measure with a spirit level. If the floor is uneven or has a
decided slope, level the unit with metal shims.
NOTE: A caster may not return exactly to the same position after being moved, which may require re-leveling after
each move
.
3. Connect the gas manifold to the building gas supply line by means of an approved flexible gas line as shown in the figure
below.
NOTE: 3⁄4" (19mm), 1" (25mm) and 1 1⁄4" (32mm) flexible gas hoses 4 feet long (1219mm) with a quick disconnect
coupling on one end are available from Ultrafryer Systems under PN 24322 (3⁄4" (19mm) hose), PN 24323
(1" (25mm) hose) and PN 24456 (1 1⁄4" (32mm) hose). These hoses are equipped with a fusible link, which
melts at 361°F (183ºC) that will SHUT OFF the gas supply when it melts. A 44" (1119mm) long restraining
device is also available under PN 24324.
1. BUILDING GAS SERVICE LINE
6. APPLIANCE MANIFOLD/NIPPLE
2. MAIN GAS CUT-OFF VALVE
7. EYELET FASTENERS
3. CONNECT-IT QUICK-DISCONNECT
8. SPRING HOOK
4. FLEX-CON CONNECTOR
9. RESTRAINING CHAIN
5. ELBOW
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND
MAINTENANCE INSTRUCTIONS THOUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIP-
MENT. PARTS AND ADJUSTMENTS PROTECTED AND SEALED BY MANUFACTORER OR THEIR
AGENTS ARE NOT TO BE ADJUSTED BY THE USER.
WARNING: THE RESTRAINT DEVICE (ITEM 9) MUST BE INSTALLED TO ASSURE TENSION
CANNOT BE PLACED ON THE FLEXIBLE GAS LINE OR FITTING.
Page 7
30A134
TYPICAL GAS CONNECTION
CAUTION:
THE BUILDING GAS SUPPLY LINE MUST BE SIZED TO PROVIDE THE VOLUME OF GAS REQUIRED
FOR PROPER OPERATION AS EXPLAINED IN THE EUROPEN PRESSURE, GAS AND CATEGORIES TABLE ON
PAGE 4a-4c.
RECEIVING AND INSTALLING
Summary of Contents for PAR-3-14HE CE
Page 9: ...4a 30A134...
Page 10: ...30A134 4b...
Page 11: ...30A134 4c...
Page 28: ...D DISPLAY DESCRIPTIONS 30A134 Page 21...