-After soaking,rise it in fresh water.
-Let it in a shaded and well ventilated place. Forced drying by heat or compressed air is prohibited.
Note : Water applied to rinse the element should not have a pressure of more than
2.8kgf/
㎠
㎠
㎠
㎠
(39.8psi).
An element which has been washed 5 times must be replaced with a new one.
5.ELEMENT INSTALLATION
Install the element in the reverse order of disassembly, but follow these instructions.
1) Each tightening bolt must be secured and care must be taken not to miss the packing and washers.
2) Before installing the element,clean the rubber packing on the top of the element.
Note : The wing bolt retaining the element should be tightened sufficiently so that it will not become
loose during operation
3-10
Summary of Contents for T233 HST
Page 14: ...1 11...
Page 15: ...1 12...
Page 22: ...SECTION 3 GEAR TRAIN DIAGRAMS FIG 1 3 GEAR TRAIN DIAGRAM 1 19...
Page 33: ...SECTION 2 OPERATION CHART FOR DISASSEMBLY AND REASSEMBLY BY MAJOR BLOCKS 2 4...
Page 60: ...3 HST main pump case 4 5...
Page 64: ...6 Hydrostatic system schematic 4 8...
Page 100: ...3 Rear transmission case 5 15 Fig 5 23...
Page 121: ...Power Train Diagram Fig 5 60 5 36...
Page 210: ...SECTION 6 WIRING DIAGRAM 10 12...