3. Programming
D-306488 WK250 Installer’s Guide
67
Step 1
Step 2
Enter “09:FACTORY DEFLT” menu
[1]
Select "leave KP250" or "del all
devices"
[2]
09:FACTORY DEFLT
09:FACTORY DEFLT
leave KP250
or
09:FACTORY DEFLT
del all devices
Step 3
Step 4
Press
[3]
Enter the Installer Code
[4]
<OK> to confirm
Leave KP250
ENTER CODE
or
<OK> to confirm
del all devices
Communicating
<…>
– Performing Factory Default
[1]
Enter the
Installer Menu
and select the
"09:FACTORY DEFLT "
menu (see section 3.2).
[2]
Select “leave KP250” to reset factory default parameters, or, press
and select “del all devices” to delete all
devices in the system.
[3]
Press
to confirm.
[4]
Enter the Installer Code (9999 by default).
Notes:
1) There is a brief pause after which all factory defaults are restored or devices are deleted from the system.
2) To abort the procedure, press
to return to “09:FACTORY DEFAULT” or
to take you to “<OK> to
Exit".
Notes:
1. For WK250 with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master installer code
enables to perform the factory default function.
2. If the Soak Test is active, performing factory default will restart the Soak Test.