3. Programming
18
D-306488 WK250 Installer’s Guide
- Configuring New Devices
Device Configuration:
[9]
To review or change the
Device Configuration
(settings)
, press the
button, otherwise scroll to the
next option – see
[11].
[10]
To configure the device parameters, refer to its corresponding device datasheet in the device Installation
Instructions. The defaults of the device parameters can be also configured as explained in section 3.4.7.
[11]
After completing the configuration of the device, the wizard brings you to the
"Next Step"
menu with the
following 3 options:
"
NEXT Device
" to enroll the next device.
"
MODIFY Same Dev.
" reverts to Step 1 (i.e. "
LOCATION
") to allow you to perform additional changes to the
device, if needed.
"
EXIT Enrollment
" exits the enrollment procedure and returns to Step 1 bringing you back to the "
ADD
NEW DEVICES
" menu.
Location List
No.
Location
Name
No.
Location
Name
No.
Location
Name
No.
Location
Name
01
Attic
09
Downstairs
17
Living room
25
Master bath*
02
Back door
10
Emergency
18
Office
26
Master Bdrm*
03
Basement
11
Fire
19
Upstairs
27
Custom 1
∗
04
Bathroom
12
Front Door
20
Utility room
28
Custom 2
∗
05
Bedroom
13
Garage
21
Yard
29
Custom 3
∗
06
Child room
14
Hall
22
Dining room*
30
Custom 4
∗
07
Closet
15
Kitchen
23
Garage door*
31
Custom 5
∗
08
Den
16
Laundry room
24
Guest room*
WP8010:
All location names be customized by “06:CUSTOM NAMES” menu (see section 3.8)
∗
WP8030 / WP8033:
Can be customized by “06:CUSTOM NAMES” menu (see section 3.8)
Zone Type List
Zone No. and Type
Description
Zxx: ZONE TYPE
1.Exit/Entry 1
This Zone starts the exit time when the user arms the system or the entry time
when the system is armed. To configure the Exit/Entry 1 time, see sections 3.5.1 &
3.5.2 - Installer menu "
03.CONTROL PANEL
" options 01 and 03. (
∗
)
Zxx: ZONE TYPE
2.Exit/Entry 2
Same as Exit / Entry 1 but with a different delay time. Used sometimes for entrances
closer to the panel. For configuring the Exit and Entry 2 delays, see sections 3.5.1 &
3.5.2 – Installer menu "
03.CONTROL PANEL
" options 02 and 03. (
∗
)
Zxx: ZONE TYPE
3.Home Delay
Used for Door/Window Contacts and Motion sensors protecting entrance doors to
interior living areas where you wish to move feely when the system is armed
HOME. Functions as a "Delayed" zone when the system is armed HOME and as a
"Perimeter Follower" zone when the system is armed AWAY.
Zxx: ZONE TYPE
4.Inter-Follow
Similar to "Interior" zone but temporarily ignored by the alarm system during
entry/exit delay periods. Usually used for sensors protecting the route between the
entrance door and the panel.
Zxx: ZONE TYPE
5.Inter
This zone type generates an alarm only when the system is armed AWAY but not
when the system is armed HOME. Used for sensors installed in interior areas of the
premises that needs to be protected when people are not present inside the
premises.
Zxx: ZONE TYPE
6. Perimeter
This zone type generates an alarm when the system is armed both in AWAY and
HOME modes. Used for all sensors protecting the perimeter of the premises.