3. Programming
66
D-306488 WK250 Installer’s Guide
Message
Description
BROADBAND MODULE
CABLE UNPLUGGED
The Ethernet cable is not connected to the Broadband Module.
BROADBAND MODULE
Check lan config
This message appears in any of the following cases:
•
Incorrect Broadband Module IP has been entered.
•
Incorrect subnet mask has been entered.
•
Incorrect default gateway has been entered.
•
DHCP server failure.
BROADBAND MODULE
RCVR#1 UNREACH
Receiver 1 or 2 is inaccessible, as follows:
•
Wrong receiver IP has been entered.
•
Receiver failure.
•
WAN Network failure.
BROADBAND MODULE
RCVR#2 UNREACH
BROADBAND MODULE
RCVR#1 UNREG
The WP unit is not registered to IP receiver 1 or 2.
BROADBAND MODULE
RCVR#2 UNREG
BROADBAND MODULE
TIMEOUT ERR.
Broadband Module does not respond to test result within 70 sec.
BROADBAND MODULE
INVALID RESULT
Broadband Module responds with a result code that is not recognized by the WP.
3.10 User Settings
This USER SETTINGS menu provides you with a gateway to the user settings through the regular user menus.
Refer to the WK250 User’s Guide, Chapter 6 for detailed procedures.
3.11 Factory Default
The FACTORY DEFLT menu enables you to reset the WK250 parameters to the factory default parameters or to delete
all the PowerG devices that are enrolled in the system. To obtain the relevant parameters defaults, contact the WP
dealer. Reset factory default parameters as follows: