3. Programming
D-306488 WK250 Installer’s Guide
53
3.6.8 Broadband
Note:
If the Broadband Module is not registered to the WP, the menu "
7:BROADBAND
" will not be displayed on the
WK250.
In this section you can configure how to obtain an IP address, enter LAN parameters and reset broadband module
settings.
04:COMMUNICATION
⋅ ⋅ ⋅
7:BROADBAND
⋅ ⋅ ⋅
MENU you wish
Enter "
7:BROADBAND
", select the menu to configure (see guidance above and in section 3.6.1), then refer to the table
below for configuration instructions.
Option
Configuration Instructions
DHCP CLIENT
DHCP ENABLE
Define whether to obtain an IP address automatically using a DHCP server or to enter an
IP address manually.
Options:
DHCP
DISABLE
and
DHCP ENABLE.
MANUAL IP
Manually enter LAN parameters.
IP ADDRESS
192.168.000.200
Enter the IP address of the Broadband Module
SUBNET MASK
255.255.255.200
Enter the subnet mask used with the IP address.
DEFAULT GATEWAY
192.168.000.001
Enter the default gateway of the Broadband Module.
Note:
If DHCP CLIENT is set to DHCP ENABLE, the entries for IP ADDRESS, SUBNET
MASK and DEFAULT GATEWAY will be ignored.
RESET MODULE
Determine whether to reset the broadband module or to reset all broadband settings –
does not reset Monitoring Station IP settings. (FACTORY DEFIN.).
REBOOT
Press ‘OK‘
Resets the broadband module
FACTORY DEFAULT
Press ‘OK‘
Resets all broadband settings