3. Programming
D-306488 WK250 Installer’s Guide
65
Message
Description
APN not defined
APN is not configured.
SIM card locked
After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it
enter a PUK number. The PUK number cannot be entered by the control panel.
Denied by server
PowerManage denies the connection request. Check that the panel is registered to
PowerManage
3.9.4 Testing the SIM Number
The WP enables to test the SIM number to ensure the SIM number was entered correctly in the control panel (see
section 3.6.7) and to coordinate with the operator.
07:DIAGNOSTICS
⋅ ⋅ ⋅
SIM NUMBER TEST
⋅ ⋅ ⋅
Tst by IP RCVR 1
Enter the "
SIM NUMBER TEST
" menu, select the IP server (out of two) used for the verification of the SIM and press
. The panel sends a test SMS to the server.
If the server receives the SMS, the WK250 will display “
SIM# verified
” and the test ends successfully. If the SMS was
not received, for example, if there is no connection between the control panel and server, the WK250 will display “
SIM
not verified
”.
3.9.5 Testing the Broadband/PowerLink Module
The Broadband diagnostic procedure enables to test the communication of the Broadband Module (see section 3.6.8)
with the PowerManage server and reports the diagnostic result. In case of communication failure, detailed information of
the failure is reported.
07:DIAGNOSTICS
⋅ ⋅ ⋅
BROADBAND MODULE
⋅ ⋅ ⋅
PLEASE WAIT… Unit is OK
Notes:
1.
When the
button is pressed, the test result may take up to 4 min. before it is displayed.
2.
If the Broadband Module is not registered to the WP, the menu "BROADBAND MODULE" will not be displayed.
The following table presents the list of messages that may be reported:
Message
Description
BROADBAND MODULE
UNIT IS OK
Broadband Module is functioning correctly.
BROADBAND MODULE
TEST ABORTED
The diagnostic test is aborted, as follows:
•
AC failure – Broadband Module is set to OFF mode.
•
Broadband Module has not completed the power-up procedure. In this case, the
installer should wait a maximum of 30 seconds before re-testing.
BROADBAND MODULE
COM. LOSS
The RS-232 serial interface between the Broadband Module and the WP failed.
BROADBAND MODULE
BBA RCVR IP MISS
Receivers IP 1 and 2 settings are missing in the WP.