Air Tools TERMI-POINT
(diverse types)
©2013 Tyco Electronics AMP GmbH, a TE Connectivity company.
All rights reserved.
TE Connectivity, TE connectivity (logo), TERMI-POINT and Tyco
Electronics are Trademarks.
60/ 64
Customer Manual
412-18008 Rev. D1
* Other products, logos and company names mentioned herein may be trademarks of their respective owners
15.4.2.2 Check Clip Position
Refer to Fig. 33 and check clip position on post for the following criteria:
1.
First clip on post must not bottom on panel or on chamfer of post.
2.
At least isolation diameter serves as free space for first clip on post.
3.
Additional clips on post may seat on each other but must not override.
4.
Last clip on post must not be positioned closer than 1.6 mm (ref.) and 1.2 mm (min.) to top of
post.
Fig. 33: Clip Position Check
1
Back end of clip
2
Clips may seat on each other
3
Clearance equal to or greater
than insulation diameter
4
Clips must not override