15.2 Operator’s Quality Check Procedure
15.2.1 Quality Control Procedure for TERMI-POINT Clip Applications
(per GP 1920, Rev. Germany 3/86)
The following recommended procedure is intended as a guide in establishing quality control criteria for
TERMI-POINT clip when applied to Tyco Electronics AMP GmbH posts with TERMI-POINT tooling.
Individual requirements will dictate the extent of the quality control program.
15.2.1.1 Initial Process Qualification
1.
Make certain that proper clip, wire post and application tooling are used. Refer to Publication
GP 1935.
2.
Apply at least 15 samples to posts in accordance with instruction material packaged with ap-
plication tool.
3.
Remove samples from post and inspect for proper insulation stripping or wire damage that is:
a.
No insulation between clip and wire.
b.
Metal-to-metal contact must be maintained between clip and wire and between wire and
post.
c.
No missing or nicked wire strands.
4.
If requirement 3 is met,apply 50 samples to posts, 2 clips per piece, in accordance with in-
struction material packaged with
5.
Check samples per Publication GP 2019; if requirements are met, tensile tests should be
made using the following procedure:
a.
Use a Hunter Spring Gauge L 10 M, or equivalent. The gauge must be calibrated and
provide consistent results.
NOTE
Refer to Publication IS 1933, GP 1935 and GP 2019!
NOTE
Beachten Sie dazu das Datenblatt GP 1935!
NOTE
Insulation silvers are permitted in other areas as shown on GP 2019.