V02.00 | 2019/10
77
Instance 120 – 4 byte IN/4 byte OUT, diagnostics
The description of the input data can be found in chapter “Operating” [
Word
no.
Bit no.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Status word
0x00
-
FCE
-
-
-
-
V1
-
V2
-
-
-
-
-
-
Diag
Inputs
0x01
-
DI14
(SIO)
-
DI12
(SIO)
-
DI10
(SIO)
-
DI8
(SIO)
DXP7 DI6
(SIO)
DXP5 DI4
(SIO)
DXP3 DI2
(SIO)
DXP1 DI0
(SIO)
Process input data valid
0x02
-
DVS
14
-
DVS
12
-
DVS
10
-
DVS8 -
DVS6 -
DVS4 -
DVS2 -
DVS0
IO-Link process input data
0x03…
0x04
2 words per port
…
0x11…
0x12
Diagnostics
VAUX1/VAUX2
0x13
VERR
V2 C7
ch15
VERR
V2 C6
ch13
VERR
V2 C5
ch11
VERR
V2 C4
ch9
-
-
-
-
VERR
V1 C7
ch14
VERR
V1 C6
ch12
VERR
V1 C5
ch10
VERR
V1 C4
ch08
VERR
V1 C3
ch6/7
VERR
V1 C2
ch4/5
VERR
V1 C1
ch2/3
VERR
V1 C0
ch0/1
DXP channels
0x14
-
-
-
-
-
-
-
-
ERR
DXP 7
-
ERR
DXP 5
-
ERR
DXP 3
-
ERR
DXP 1
-
IO-Link port diagnostics
Port 1
0x15
GEN
ERR
OVL
V
HIGH
V
LOW
ULVE LLVU O
TMP
PRM
ERR
EVT1
EVT2 PD
INV
HW
ERR
DS
ERR
CFG
ERR
PPR
-
…
Port 8
0x1C
GEN
ERR
OVL
V
HIGH
V
LOW
ULVE LLVU O
TMP
PRM
ERR
EVT1
EVT2 PD
INV
HW
ERR
DS
ERR
CFG
ERR
PPR
-