Smart Load OFF Batt
: SOC of the battery when load will turn off
Smart Load ON Batt
: SOC of the battery when load will turn on. The condition
of solar production being above the value of ‘’Power’’ must happen
simultaneously.
On Grid always on
: The load connected to Gen Port will always be fed if
there is Grid
Micro Inv Input
: Use of the as micro-inverter entry or on-grid inverter.
Micro Inv Input OFF
: When the SOC of the battery exceeds this value, the
inverter or microinverter will stop working.
Micro Inv Input ON:
When the SOC of the battery reaches this level, the
inverter or microinverter will start working.
AC Couple Fre High
: With this option selected, when SOC is reachong the
OFF value, the microinverter power goes down lineally. When the SOC
reaches the OFF value, the frequency of the system goes equal to the
selected value and the microinverter stops working.
5.11.
Advanced Function Setup Menu
5.12.
Inverters on Parallel
Solar Arc Fault On:
USA market.
System Selfchec:
Disabled
Gen Peak Shaving:
If selected, when the
power demanded to the inverter exceeds a
determened value, the inverter gives the
energy difference to not go above that
1.
Select Parallel
2.
Choose a master inverter, and the slaves.
3.
Choose a Modbus number to each inverter
to be on parallel (they must be different)
4.
Configurate all the inverters to the same
phase
5.
In case of including Meters, must select
Ex_Meter For CT. Choose the same phase to
all the inverters.