Menu 1:
Generator
Menu 2:
Grid
Start
Indicates the charge level of the
Indicates the amperage de the charge from
the battery
(recomended 40A)
Gen Max Run Time:
Configurate on 24.0 hous
Gen Down Time
:
Configurate on 0.0 hours
battery to start charging
Lithium Mode:
Select according to the BMS
protocol of the battery
Shutdown:
The inverter will shut down if the SOC
goes below 10%
Low Batt:
The inverter will alarm when the
inverter goes below 10%
Restart:
The inverter will turn on back when the
battery reaches this level of charge
On this screen the configuration by tension for
batteries is made. We can stablish the floating
level, absortion, equalization, etc.
Consult on the battery manual
5.7.
System Work Mode Setup Menu
Zero Export to Load:
Select this one
when the installation is off grid
Zero Export to CT:
Select this one when
the installation is on grid (we want to
read the CTs)
(
Select Solar Sell to be able to sell to
grid)
Max Sell Power:
Maximum energy
available to be sold to grid (set on the
maximum value)
Zero Export Power:
Seleted on 020
Grid Peak Shaving
: Maximum power to
take from the grid