Super Premium 30ER / 35DR / 35DRI
61
23/01/2014
P R O B L E M - S O L V I N G
In this section, we provide a list of problems, their causes as well as possible Solutions. If you experience a
problem that is not mentioned here, please contact your reseller. Keep your user manual and the serial
number of your chipper at hand.
PROBLEM
CAUSE
SOLUTION
The engine will not start.
-Safety of the emergency but-
ton activated.
-The cover is open.
-The safety sensor of the co-
ver is defect.
-Fuse melted in the branch
box.
-The battery is low.
-The power cables have been
damaged.
-The electrical valve that stops
the engine is broken.
-Turn off the safety.
-Check if the covers are clo-
sed
-Check them (see p.41)
-Replace the fuse.
-Load or replace the battery
-Check the electrical cir-
cuits.
-Check the valve.
Reduced engine power
-Filter blocked
-Blades and hammers blunt
-Replace the filter
-Grind or replace the bla-
des. Replace the hammer
inserts.
INTERVENTION BY A TECHNICIAN ON THE ELECTRICAL CIRCUIT:
Since 2008 all TS chippers offer the possibility to shunt rotation controller M18 of the
rotor. The technician can then investigate an electrical fault on the machine without
starting the engine. The shunt will stop automatically when the contact is broken.
Check the Saelen technical customer service in your area or the Saelen after sales
department. They will explain how to shunt controller M18.
Summary of Contents for Super Premium 30ER
Page 1: ...K u b o t a...
Page 2: ......
Page 64: ...Super Premium 30ER 35DR 35DRI 64 23 01 2014...
Page 65: ...Super Premium 30ER 35DR 35DRI 65 23 01 2014...
Page 66: ...Super Premium 30ER 35DR 35DRI 66 23 01 2014...
Page 67: ...Super Premium 30ER 35DR 35DRI 67 23 01 2014...
Page 68: ...Super Premium 30ER 35DR 35DRI 68 23 01 2014...
Page 69: ...Super Premium 30ER 35DR 35DRI 69 23 01 2014 120...
Page 70: ...Super Premium 30ER 35DR 35DRI 70 23 01 2014 HYDRAULIC COUPLING...
Page 75: ......
Page 76: ......