TruVision Series 7 IP Camera Configuration Manual
85
Sensitivity = 100 – S1/ST*100
S1 stands for the target body part that enters the pre-defined region ST stands for
the complete target body.
Example: if you set the value as 60, a target is possible to be counted as an
unattended baggage only when 40 percent body part of the target enters the region.
10. Repeat the above steps to configure other regions. Up to four regions can be set.
You can click the Clear button to clear all pre-defined regions.
11. Click Arming Schedule to set the arming schedule.
12. Click Actions to select the linkage methods.
13. Click Save to save the settings.
Object removal detection
This function detects the objects removed from the pre-defined region, such as the
exhibits on display. It can be set up to trigger a series of alarm actions. Please note that
this feature is not able to properly detect removed objects in complex and low contrast
environments.
To set up object removal detection:
1. Click
Configuration
>
Event
>
Smart
Event
>
Object Removal Detection
.
2. Select the
Enable
check box to enable the function.