![TruVision 7 IP VF TVD-5715 Configuration Manual Download Page 75](http://html1.mh-extra.com/html/truvision/7-ip-vf-tvd-5715/7-ip-vf-tvd-5715_configuration-manual_1177458075.webp)
TruVision Series 7 IP Camera Configuration Manual
71
3. Select the
Sudden Increase of Sound Intensity Detection
check box to detect the
sound steep rise in the surveillance scene. You can set the detection sensitivity and
threshold for sound steep rise.
4. Select the
Sudden Decrease of Sound Intensity Detection
check box to detect
the sound steep drop in the surveillance scene. You can set the detection sensitivity
and threshold for sound steep drop.
Notes
:
Sensitivity: Range [1-100], the smaller the value is, the more severe the change
should be to trigger the detection.
Sound Intensity Threshold: Range [1-100], it can filter the sound in the environment,
the louder the environment sound, the higher the value should be. You can adjust it
according to the real environment.
You can view the real-time volume of the sound on the interface.
5. Click
Arming Schedule
to set the arming schedule.
6. Select
Actions
and select the linkage methods for audio exception:
Normal Actions
This is a group selection. It automatically selects “Send Email”
and “Notify Alarm Recipient”
Send Email
Sends an email to a specified address when there is a motion
detection alarm.
Note: You must configure email settings before enabling this
option. See “To set up the email parameters” on page 42 for
further information. If you want to send the event snapshot
together with the email, select the Attached Snapshot option.
Notify Alarm Recipient
Send an exception or alarm signal to the remote management
software when an event occurs.