The foot switch has the following positions:
Position
Description
The foot switch is not
pressed.
The press beam is stationary or remains sta-
tionary.
The foot switch is
pressed as far as the
first pressure point
(neutral position).
The press beam moves downwards.
The foot switch is
pressed all the way
down.
The stop function leads to the following:
■
Control stops.
■
The press beam stops.
■
Stop all axis motions of the backgauge.
■
The hydraulic unit is switched off.
Tab. 1-4
The press beam can be moved upwards using the PRESS
BEAM UP foot switch.
The foot switch has the following positions:
Position
Description
The foot switch is not
pressed.
No effect on the press beam.
The foot switch is
pressed.
Hydraulic system switches on.
The press beam moves upwards.
Tab. 1-5
The PRESS BEAM UP foot switch is not active in the following
cases:
■
EMERGENCY STOP was triggered.
■
One or both side protection doors were opened.
■
The rear safety door was opened.
There is a key switch for the maintenance work.
The key switch is located on the rear side of the machine.
The key switch has the following positions:
Position
Description
0
The power supply to the machine will be interrupted when
the switching cabinet door is opened.
The key must be removed and kept safely.
I
The power supply to the machine remains switched on
when the electrical cabinet door is opened.
Tab. 1-6
B1161en
2019-07-09
Measures to be taken by the manufacturer
1
‐
15
PRESS BEAM DOWN foot
switch with stop function
PRESS BEAM UP foot
switch
USA, Canada, Mexico,
South America: Key switch
for DEACTIVATE DOOR
LOCK