Vibration damping can be implemented by the following meas-
ures:
■
Use Sylomer mats to isolate the machine; thickness 12 mm
(0.47 in), quality SR 1200, violet color, foundation plate to
the subsurface and on the side.
■
Structure of the floor (from the bottom to the top):
−
A layer of construction mat.
−
At least 300 mm (11.8 in) gravel layer with compaction.
−
120 mm (4.72 in) underbody C12/15 reinforced with 1
mild steel grid layer (steel cross-section lengthwise/cross-
wise 1.96 cm²/m, mesh width lengthwise/crosswise
100 mm, wire thickness lengthwise/crosswise 5 mm).
2.3
Weight load
■
Perform a structural stress analysis of the load-bearing
capacity of the floor surface prior to installation.
■
Take into account the weights of the relevant components
and the load on the support points.
Note
If the concrete floor has the minimum thickness and quality, it
will not have to be subject to a structural check.
TruBend
2100
Weight of machine
7500 kg
(16534 lb)
Static load on each support point, front
32.8 kN
Dynamic load per front support point
40.9 kN
Static load on each support point, rear
5.7 kN
Dynamic load per rear support point
6.2 kN
Weight support at the front per base on a surface area of ...
80 x 80 mm
(3.2 x 3.2 in)
Weight support at the rear per base on a surface area of ...
80 x 80 mm
(3.2 x 3.2 in)
Weight load: (X) = enlarged open height
Tab. 2-4
2.4
Stress due to vibration
In the immediate area around the system, external influences
can lead to vibration loads. Vibration stress can effect the qual-
ity of workpieces.
B1161en
Installation site - Version 1
2
‐
9
Structural analysis