Failure: The refrigerator does not cool in
230 V operation.
Possible cause
Action you can take
On-board fuse defective
Fit new fuse
Vehicle not connected to mains supply
voltage
Make a connection to a mains power supply
AES: Gas operation despite connection to the
mains supply voltage?
Appliance switches to gas operation due to
insufficient mains supply voltage (automatically
switches back to 230 V operation)
Heating element defective (please refer to
failure indication
Please inform Dometic Customer Services
Information on failure display and
trouble-shooting
• Refrigerators with an electronics system
(MES, AES) indicate the occurence of a
malfunction by the LED or display flashing.
• If a malfunction occurs, the indicator LED
“Failure” (8) flashes simultaneously. In the
case of AES models an acoustic alarm
sounds.
Before notifying the authorised Service Center,
please check whether:
• the instructions in section “Operating the
refrigerator” have been observed.
• the refrigerator stands level.
• it is possible to operate the refrigerator with
any available power source.
Status indicators
MES
Fig. 51
1
2
3
4
6
7
8
1 -
Button ON / OFF
2 -
Energy selector switch 230 V AC
3 -
Energy selector switch GAS
4 -
Energy selector switch 12V DC
6 -
temperature level button
7 -
temperature level display
8 -
fault LED / GAS FAULT reset button