FITTED EQUIPMENT
102
d = boost *
(Targeted, fast heating of the content of the
boiler [boiler priority]. The water temperature
is kept at the higher level [around 62 °C] – Not
Combi Diesel. Once the water temperature is
reached, the room is heated again.)
* This symbol will flash until the required water
temperature is reached.
Select power type
• Use the control knob / push button to select
the symbol in menu line (3).
• Click to change to the setting level.
• Use the control knob / push button to select
the required power type.
• Click the control knob / push button to
confirm the value.
2
3
a
b
c
Symbol
Operating mode Power type
a
Gas
Gas
b
EL 1
Electro
b + c
EL 2
Electro
a + b
Mix 1*
Gas + Electro
a + b + c
Mix 2*
Gas + Electro
* Mixed mode
Special aspects in the mixed mode
Interruption of the power supply 230 V
Combi Gas
The heater automatically switches to the gas
mode. As soon as the 230 V power supply is
reconnected, the heater automatically switches
back to the mixed mode.
Malfunction in the combustion process
(e.g. lack of fuel)
Combi Gas
The heater automatically switches to the
electro mode. If the heater should operate
in the mixed mode again, the cause of the
malfunction needs to be rectified. Switch the
heater off and on again on the control panel.
Select fan level
When the heater / air conditioning unit is
connected.
• Use the control knob / push button to select
the symbol in menu line (3).
• Click to change to the setting level.
• Use the control knob / push button to select
the required fan level.
• Click the control knob / push button to
confirm the value.
2
3
a
b
c
d
e
f
TRUMA CP PLUS DIGITAL TIMER CONTROL