FITTED EQUIPMENT
122
10. Offset (temperature adjustment)
Using this function, you can calibrate
the temperature on the panel if you
notice that the temperature (the
stabilised room temperature) is not the
same as the temperature shown on
the panel. This also applies to outdoor
temperature.
11. Button sound
With this function, you can activate
or deactivate the button sound. The
button sound is activated in the factory
setting.
12. Screen Brightness
Brightness: The brightness of the
display (working mode) can be adjusted
from 1 to 10. Factory setting is 5.
Standby brightness:
Off:
Used to turn the display’s
backlighting off so that the display is
turned off (becomes dark) in standby
mode (the LED is still active).
On:
Used to activate the backlighting
in the display (low lighting) in standby
mode (the LED is still active). Factory
setting is On.
Lan
13. Language
This function is used to reset the screen
between different languages. Available
languages are: English, French and
German. On the other hand, the service
menu is only in English (see section
10.1).
14. Tools / Key
Under Tools / Key you can lock or
unlock access to the tool menu.
Ext
15. *External start
This function is used when starting the
boiler from the outside, for example,
with GSM. When external start has
been activated, the control panel’s
On/Off button must be switched off
(see the assembly setting manual for
external start).
Note:
To use this function, an external start
installation is required (see the manual for
the vehicle, boat or building).
*230 V
This function is used in connection with
starting the boiler when connection of 230
V to vehicle takes place from outside. When
the 230 V function has been activated the
control panel’s on/off button must be turned
off, but 12 V must be connected (the vehicle’s
main switch is on). Before turning off the
control panel with the on-/ off button set the
parameters/functions that you want the boiler
to have when it starts (230 V is connected).
Amp
16. *Load monitor
This function is used to prevent the
230V fuses being overloaded. If the
total power consumption of the vehicle,
boat or building exceeds the set value,
the boiler’s power will be automatically
reduced. On account of voltage
variations and tolerances, different
setting levels can be selected (for
example, for 6A fuse, one can choose
6 or 7 Amp setting). If the fuse does
not hold, choose a lower set value. The
function is deactivated in the factory
setting.
Note:
The load monitor has to be installed
for the function to be used (see the manual
for the vehicle, boat or building).
10. Service and Resetting
the system
1
2
4
3
ALDE HEATING OPERATING INSTRUCTIONS