User Manual Qiwi Lite
Support: www.tronteq.de/support
Release 11/2016
Seite 30 von 31
Fault Contact
Parameter
min.
typ.
max.
Dim.
Switching voltage
AC
DC
-
-
-
-
30
60
VAC
VDC
Switching current (SELV)
-
-
1
A
Digital Input
Parameter
min.
typ.
max.
Dim.
Low level (logic 0)
-0.3
0
5
VDC
High level (logic 1)
11
24
30
VDC
Isolation
Parameter
min.
typ.
max.
Dim.
Data ports
↔ data ports
± 2250
-
-
VDC
Data ports
↔ V1, V2, USB, fault contact
± 2250
-
-
VDC
Data ports
↔ housing (grounding)
± 2250
-
-
VDC
Fault contact
↔ V1, V2, USB, housing
± 1500
-
-
VDC
Housing (grounding)
↔ V1, V2, USB
± 850
-
-
VDC
Data ports
↔ data ports
± 2250
-
-
VDC
12.2. Mechanical
Parameter
typ.
Dim.
Dimensions (H x B x T, ± 0,5 mm)
64 x 105 x 48
mm
Mass net
250
g
Housing protection class
IP20
-
12.3. Environment
Parameter
min.
typ.
max.
Dim.
Ambient temperature during operation
-40
-
+70
°C
Ambient temperature storage
-40
-
+85
°C
Humidity (not condensing)
10
-
95
%
Air pressure during operation
795
(+2000m)
-
-
hPa
13. Licenses
The firmware of the Qiwi consists of files that are licensed, one part is Open Source. The following