Veefil-RT 175-S Site Installation Manual
TRI125.INS.018 version 1
4 March 2020
Manual
Page 23 of 25
4.7.6
Terminate safety loop cable
Feed the safety loop cable through the gland.
Note:
If a 3-core cable is supplied only 2 cores are required, the third (earth) conductor
should be taped and stowed.
Strip and apply bootlaces to the cable if stranded, no bootlace if solid core.
Insert the cable into the green connector on the tilt sensor PCB, the polarity of this
connection does not matter.
Note:
This is the PCB located on the bottom-right of Figure 19.
4.7.7
Terminate single phase cable
Feed the single-phase cable through the gland.
Note:
When terminating the 3-core cable, do not terminate the Earth to common
chassis Earth terminal. This core will be used for the IMI reference point.
Strip and apply bootlaces to the cable if stranded, no bootlace if solid core.
Insert the cable into the designated field wiring terminals to the top-left of the
connection box.
Note:
For internal wiring, brown denotes 230VAC line and blue denotes 230VAC
neutral.
Close the hatch and tighten all cover screws to 2Nm.
4.7.8
Terminate Ethernet cable
Unscrew the Ethernet IP connector from the HMI screen.
Slide housings mating half over the Ethernet cable coming from the conduit.
Note:
Ensure that the housing does not slide all the way back into the conduit.
Terminate the Ethernet cable into the Cat6A tool-less jack from the installation kit using
Mode A.
Note:
Ensure that you connect shield to equipment ground on both the IPU and UU
ends.
Figure 20: Cat6A tool-less.
Slide the housing cover back up over the jack as shown in
Figure 21: Terminated Ethernet jack.
Remove and discard Female to Female inline connector from housing.
Connect Ethernet cable from the HMI and close the housing.
Note:
Make sure that the housing is tightened in the middle and at the two end nuts to
ensure a waterproof seal.