www.trilithic.com
Page IV-10
180 DSP Operation Manual
Signal Level Meter
Analog Channel Measurement
When an analog channel is selected, the
Level
screen will display the following
information:
• Reference Level (adjustable)
• Vertical Scale (adjustable)
• Channel Number (adjustable)
• Channel Name
• Video Center Frequency (adjustable)
• Audio Center Frequency (adjustable)
• Display Type (adjustable)
Measurement Results
The following measurement results are displayed with a pass/fail status for each
measurement that is included in the open limit set:
• Video level value with bar graph
• Audio level value with bar graph
• Video/Audio delta value
• C/N value