Control panel SP231
Programming and control by SMS messages
©1997-2015 Trikdis
52
www.trikdis.com
7
Programming and control by SMS messages
The alarm system can be controlled and some parameters of the control panel can be changed by means of
SMS messages. All the control panel parameters can be changed by TrikdisConfig only.
To change the desired parameter of the control panel by SMS message, the SMS message of the following
syntax must be sent:
PSW[password]
space
[Command code]
space
[Command content]
SMS messages must be started with capital letters PSW and 6-digit remote login password entered in the
control panel.
Symbol
"
˽
"
in the table means a space symbol in SMS text.
The control panel will send SMS message, reply to inquiry to the particular phone from which the inquiry was
received.
SMS command text
Description
CFGxxxxxx ˽ 01 ˽ CCCC # PPPPPPPPP #
Adds phone number to user. Command can be sent from
any phone number.
01 – command number, CCCC – user code, PPPPPPPPP –
user phone number.
Example adding a phone number to the user which code is
“1234”:
“CFG123456 01 1234#+37061111111#”
PSWxxxxxx ˽ 10 ˽ AAA.AAA.AAA.AAA#PPPP#
Set the first IP address and port number.
AAA.AAA.AAA.AAA
–
IP address
PPPP
–
Port number
PSWxxxxxx ˽ 11 ˽ AAA.AAA.AAA.AAA#PPPP#
Set the second IP address and port number.
AAA.AAA.AAA.AAA
–
IP address
PPPP
–
Port number
PSWxxxxxx ˽ 12 ˽
APN#LOGIN#PSW#ENC#PING#
Set SIM1 card access to GSM network settings. And
general network settings.
APN
–
access name (up to 50 characters) ,
LOGIN
–
user name (up to 29 characters)
PSW
–
user password (up to 29 characters)
ENC - data encryption key (6 characters)
PING
–
report sending interval (10
–
65000).
After each value, enter the end symbol #,
e.g., PSWxxxxxx 12 APN#LOGIN#PSW#123456#180#.
If operator requires no indication of access to APN, neither
LOGIN nor PSW, then SMS message should look in such a
way:
PSWxxxxxx 12 APN###123456#180#
PSWxxxxxx ˽ 13 ˽ APN#LOGIN2#PSW2#
Set SIM2 card access to GSM network settings.
APN
–
access name (up to 50 characters) ,
LOGIN
–
user name (up to 29 characters)
Note. You must replace the factory set remote login code (123456) with the code known to you only, e.g., with