Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
19
www.trikdis.com
6
Configuration of control panel operation
The control panel operation parameters shall be set by software TrikdisConfig, which operates in OS MS
Windows environment. It is possible to connect to the control panel by using a USB cable or remotely, by
communicating with the control panel via GPRS communication. The software is available on the website
www.trikdis.com
. Some control panel parameters can also be changed remotely by SMS messages.
6.1
Connect to control panel
6.1.1
Connect with USB cable
1)
The computer shall have installed the following: parameter setting software TrikdisConfig and
software Microsoft.NET Framework 4.
2)
After the software is in place, connect the control panel and the computer with the USB cable. Power
supply via USB port is sufficient to set the control panel operation parameters, so additional supply
is not necessary. Start the parameter setting software TrikdisConfig. The software shall automatically
recognise the connected device and open the window for its programming.
3)
In order to read the parameters entered in the control panel, click the button Read and in the pop-
up table enter your (Admin or Installer) code (if the administrator initial code exists, the code shall
not be prompted).
4)
After the first time reading of the control panel operation parameters, the software shall show the
manufacturer set default control panel operation parameters. After changing the parameters, click
the software button Write to enter the changes in the control panel memory. When configuration is
complete, shut down the software TrikdisConfig and unplug the USB cable from the control panel
USB port.
6.1.2
Connect in remote mode
Configuration of the control panel settings in remote mode shall be carried out via GPRS communication. For
both softwares TrikdisConfig and IPcom the appropriate GPRS communication settings shall be set. The manual
of the control panel shows how to do it and how to connect by using TrikdisConfig software. The description
how to connect with IPcom software is provided in the supporting documentation to this software.
6.1.2.1
GPRS communication settings
1)
Ensure that SIM card has a disabled PIN code protection.
2)
Insert SIM card with enabled GPRS communication service into the control panel SIM 1 slot. For
information how to enable this service please contact Your GSM service provider.
3)
Add phone number the user, because only from listed numbers it is available to use all SMS commands.
SMS commands must be sent to the inserted SIM card’s number.
Command to add new phone number:
CFG [SMS password] ˽ 01 ˽ [USER Code] # [User Phone No.] #
CFG – beginning of SMS command, [SMS password] – six digit SMS password, 01 – command code,
[User code] – user code, [User phone No.] – user phone number, # - symbol to end value, “˽ “– marks the
space symbol in SMS message.
An example adding a phone number to Master user, while using default password values:
“CFG123456 01 1234#+37061111111#”
Note. When the Grade 2/3 protection class setting function is enabled, the remote control and
configuration function of the control panel shall be disabled automatically.