Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
47
www.trikdis.com
Cleaning siren`s memory:
Siren are saving information about receiver in its inner memory, before learning it to new receiver, memory
must be cleaned.
1)
Disconnect battery.
2)
Press and hold Learn button.
3)
Insert battery (still holding learn button).
4)
Wait until red LED will start flashing (still holding learn button).
5)
When red light stops flashing, stop pressing learn button.
6)
Sirens memory are cleaned.
6.17.3
Pendants
In this tab registered pendants and keypads will be shown.
Learning:
1)
To start “Learn” procedure, press the button Start learning.
2)
Press 3
rd
and 4
rd
buttons at the same time, orange LED will start blinking.
3)
When orange LED stops to flash – release all two buttons.
4)
In TrikdisConfig window Wireless sensors, tab Pendants, new pendant will be
shown.
Pendant registration
Name
Description
Rescan registered devices
Rescan all registered devices
Add device (serial no)
To register device enter it`s serial number and generate event (e.g. tamper)
Remove devices (serial no)
Using device serial number remove it from device list
Pendant parmeters
Name
Description
ID
Device sequence number
Serial No
Pendant`s registration number
Device type
Pendant`s type
RSSI
Received signal strength
Pendant registration
Pendant parameters
Note: Pendant also can be assign to user and partition in User window.