![Tridonic DALI MSensor 02 Product Manual Download Page 10](http://html.mh-extra.com/html/tridonic/dali-msensor-02/dali-msensor-02_product-manual_1162228010.webp)
  Commissioning and Adaptions
Documentation DALI MSensor 02 | 02-2012 | en
- 10 / 38 -
Commissioning and settings
The DALI MSensor 02 either controls all the devices on the DALI circuit or a DALI group. To enlarge the presence detection
area, it is possible to assign the same destination to several DALI MSensors 02. To achieve this, simply assign the sensors
to the same DALI group.
The DALI MSensor 02 is configured in the masterCONFIGURATOR software (V2.02. or later). The DALI MSensor 02 can be
assigned to a specific effective range. In addition, the parameters of the individual functions can be individually adjusted (
see
).There are two ways of obtaining assignment to an effective range:
chapter "Functions", page 12
Group assignment by using rotary switch
Group assignment by using masterCONFIGURATOR software
Notice
Luminaires must not belong to more than one DALI group! Otherwise the sensors will not interpret commands
sent to the luminaire correctly.
Unlike other DALI controllers, a DALI address is assigned to the DALI MSensor 02 during addressing. This
reduces the total number of available DALI addresses. This must be taken into account when designing the
DALI circuit!
Extending an existing DALI circuit
The DALI MSensor 02 can be used in an existing DALI circuit when a system is extended if the DALI
MSensor 02 controls its own group.It is not possible to operate a DALI MSensor 02 and a DALI MSensor
(V1.5 or earlier) in the same DALI group. Because of the modified grouping concept, there is no
synchronisation of constant light control and presence detection between the two equipment generations.
Group assignment by using rotary switch
The effective range of the DALI MSensor 02 is set using the rotary switch at the rear of the sensor. All control gear located
within the previously set effective range is controlled by the sensor.
Rotary switch setting Effective range (group)
0
All (broadcast)
1
0
2
1
3...9
2...8
A...F
9...14
Summary of Contents for DALI MSensor 02
Page 1: ...luxCONTROL Product manual DALI MSensor 02 ...
Page 2: ......