![Triconex Trident Planning And Installation Manual Download Page 78](http://html.mh-extra.com/html/triconex/trident/trident_planning-and-installation-manual_1162141078.webp)
62
Input/Output Modules
Trident Planning and Installation Guide
Model 9764-310 RTD/TC/AI Termination Panel
The Model 9764-310 RTD/TC/AI Termination Panel with industry-standard
signal-conditioning modules may be cabled to the Model 2352 Analog Input
External Termination Panel Baseplate. The RTD/TC/AI Termination Panel
supports 16 points and each Analog Input Module can support up to two External
Termination Panel. The input-signal conditioners are manufactured by Analog
Devices™.
The Model 9764-310 panel comes with a:
• 10-foot cable
• Mounting plate
The Model 9764-310 panel has a barrier strip with four compression screw
terminals for connecting an AI Module to 16 analog inputs. The panel accepts
power (+24 volts DC) from the AI Baseplate or from direct connection to the panel.
Note
Each 24V power source must be able to provide 0.5 amps minimally.
Note
Because the Model 9764-310 RTD/TC/AI Termination Panel connects 16
of the available 32 points, you must use two panels.
J2
1
J1
J4
J3
U1
U2
U3
U4
U5
U6
U7
U8
U9
U12
U13
U14
U15
U16
U11
CR1
P1
+
P2
C
R
1
4
KK
A
D
NN
C20
C19
C21
J6
J5
J8
J7
J10
J9
2
3
4
5
6
7
8
9
13
10
14
11
15
12
16
7
4
0
0
2
2
5
S
/N
R
E
V
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
A
N
A
L
O
G
D
E
V
IC
E
S
U10
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
PUT
IS
O
L
A
T
ED
RT
D
IN
PUT
IS
O
L
A
T
ED
RT
D
IN
PUT
IS
O
L
A
T
ED
RT
D
IN
PUT
IS
O
L
A
T
ED
RT
D
IN
PUT
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
IS
O
L
A
T
ED
RT
D
IN
P
U
T
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
7B
34
Summary of Contents for Trident
Page 1: ...Trident Version 1 2 Triconex An Invensys Company Planning and Installation Guide ...
Page 10: ...x Contents Trident Planning and Installation Guide ...
Page 16: ...xvi Training Trident Planning and Installation Guide ...
Page 53: ...Main Processor Module 37 Chapter 3 System Description Model 2101 Main Processor Baseplate ...
Page 140: ...124 Covers Trident Planning and Installation Guide ...
Page 216: ...200 Replacing Modules Trident Planning and Installation Guide ...
Page 238: ...222 Diagread Cables and Debug Connectors Trident Planning and Installation Guide ...
Page 240: ...224 Trident Planning and Installation Guide ...
Page 248: ...232 Trident Planning and Installation Guide ...
Page 264: ...248 Glossary Trident Planning and Installation Guide ...
Page 274: ...258 Index Trident Planning and Installation Guide ...