52
HVAC Settings
Span AUX1
Span AUX2
High Balance Point
Low Balance Point
Anti-Freeze
A/C Overcool
Select the hysteresis factor for stage
1 AUX Heating control. If the room
temperature is lower than the Set
Temperature by this setting, the Stage
1 AUX Heating will be turned on.
Select the hysteresis factor for stage
2 AUX Heating control. If the room
temperature is lower than the Set
Temperature by this setting plus the
Span AUX1 setting, the Stage 2 AUX
Heating will be turned on.
Select the temperature setpoint
where the AUX heating will be locked
out once the outdoor temperature is
higher than or equals to this setting.
The AUX heating will not be turned on
when it is locked out.
Select the temperature setpoint
where the Compressor heating will
be locked out once the outdoor
temperature is lower than or equals to
this setting. The Compressor heating
will not be turned on when it is locked
out.
Select the temperature setpoint
where the Heating system will turn on
automatically if the room temperature
is lower than this setting.
Select the temperature factor where
Cooling will be allowed to continue
past the Set Temperature (Cool) by
this setting to dehumidify the room.
When the Thermostat
is Online.
When the Thermostat
is Online.
When the Thermostat
is Online.
When the Thermostat
is Online.
When the Thermostat
is Online.
When the Thermostat
is Online.
Summary of Contents for TS2501
Page 1: ...User Manual TS2501 Wi Fi Smart Thermostat ...
Page 26: ...26 2 Under the Fan setting select On Fig 26 A ...
Page 27: ...27 App 1 At the App Devices tab tap on the Fan setting and select On Fig 27 A ...
Page 29: ...29 2 Under the Fan setting select as Auto Fig 29 A ...
Page 30: ...30 App 1 At the App Devices tab tap on the Fan setting and select Auto Fig 30 A ...
Page 37: ...37 App 1 From the App Devices tab tap on the Info tab 2 Tap on Mode Fig 37 B Fig 37 A ...
Page 46: ...46 13 Click Restart to restart the manual identification process Fig 46 A ...