background image

Summary of Contents for TPS 2200T

Page 1: ......

Page 2: ...tem collects and provides detailed instructions on how to disable the specific features that feedback the information https success trendmicro com data collection disclosure Data collected by Trend Mi...

Page 3: ...rategically protect your network enterprise zones A local client on the device monitors and manages activity Alternatively you can manage devices by using the Security Management System SMS console Le...

Page 4: ...1 GbE copper ports 8 1 GbE SFP ports 8 10 GbE SFP ports 4 Power supply 2 hot swappable 750W AC power supplies External storage One 8 GB CFast System fans 3 fans not replaceable Dedicated High Availabi...

Page 5: ...ot replaceable Dedicated High Availability HA port Yes Zero Power High Availability ZPHA Built in ZPHA for copper segments TPS TX Series product overview The following topics describe the components c...

Page 6: ...e following illustration for a front panel view of the TX Series 1 U 8200TX and 2 U 8400TX devices 1 I O modules 2 SP ports 3 External storage 1 8 inch SSD 32 GB 4 Stack Master LED 5 Stack LED 6 Bypas...

Page 7: ...t the TPS TX Series chassis features Fans and power supplies External storage card Ports Chassis LEDs Fans and power supplies The TPS TX Series devices include two power supplies and seven cooling fan...

Page 8: ...k LED Chassis LEDs When you turn on the device the system completes a series of component checks and then displays LED indicators to show the status of each component Stack Master status Solid green T...

Page 9: ...ics for specific requirements of the TPS TX Series devices Power requirements Cabling requirements Power requirements The 8200TX and 8400TX devices require Alternating Current AC or Direct Current DC...

Page 10: ...s and modules Avoid contact between the printed circuit boards and clothing The wrist strap only protects components from ESD voltages on the body ESD voltages on clothing can still cause damage Place...

Page 11: ...number TPNN0070 6 Segment GbE SFP Ports 12 SFP ports Port speed 1 Gbps Part number TPNN0068 2 Segment 1G Fiber SR LR Bypass Module Ports 4 Multi Mode SR Single Mode LR Fiber LC type Port speed 1 Gbps...

Page 12: ...ered up but is not yet recognized by the software The module is experiencing a fault Bypass Status Off Green Module in bypass Module in normal mode not in bypass I O module replacement On a TPS 8200TX...

Page 13: ...nt I O modules For a list of supported transceivers and cables for TippingPoint I O modules refer to I O Modules Overview Technical specifications The TPS TX Series devices have the following specific...

Page 14: ...equirements Pluggable transceivers Technical specifications Learn more about installing the device Prior to installation have the TPS CLI Reference available for configuration information Chassis fron...

Page 15: ...plies 2 Chassis features Refer to the following topics for information about the TPS 2200T chassis features System status indicator Alert indicator Fans and power supplies External storage card Ports...

Page 16: ...ans The fans for the 2200T device are redundant but not hot swappable If a failure to a fan module occurs you must replace the entire device Learn more about fans External storage card The TPS 2200T d...

Page 17: ...owing cables Two AC power cables one for each hot swappable power supply Null modem cable USB to RJ 45 for the serial console management port Pluggable transceivers Use any of the following SFP and SF...

Page 18: ...Temperature 4 to 158 F 20 to 70 C Storage Altitude No degradation up to 10 000 feet 3048 m Humidity 5 to 95 non condensing External interfaces One 1 GbE copper management port One RJ 45 console port...

Page 19: ...panel view of the TPS 440T device 1 CFast card 2 1 GbE copper ports 3 Dedicated HA port 4 Serial console port Management port 5 Alert indicator 6 System status indicator 7 Power indicator Chassis rear...

Page 20: ...g below the acceptable threshold Alert indicator Refer to the Alert indicator on the right side of the front panel to learn whether the device is in L2FB mode or not Solid Yellow Device is in L2FB inc...

Page 21: ...requirements Refer to the following topics for specific requirements of the TPS 440T device Power requirements Cabling requirements Power requirements The TPS 440T device requires Alternating Current...

Page 22: ...erence available for configuration information reference After installation of the hardware components complete the initial setup wizard as part of the installation and configuration procedures Before...

Page 23: ...stems in the future allow space in the rack for additions During the initial installation keep in mind the weight distribution and stability of the rack Install the external storage card For TPS 440T...

Page 24: ...more about I O module installation Procedure 1 To remove the blank module slide the slide latch 1 to the right and pull on the handle 2 on left module or grab point 2 on right module CAUTION Never li...

Page 25: ...fter you have reviewed all requirements for operating your product turn on the device To turn on a TPS 440T device flip the power switch on the back panel of the device To turn on a TPS 2200T 8200TX o...

Page 26: ...ccine DV Threat Digital Vaccine ThreatDV SSL inspection You can install the license package using the SMS or LSM For information about how to install the license package refer to the user guide for wh...

Page 27: ...command When you use the CLI configure the terminal emulation package to transmit a Ctrl H character when the Backspace key is pressed The SMS The SMS provides a scalable policy based operational mod...

Page 28: ...ed the device automatically powers back on when the power is reconnected if power was off the device stays off when the power is reconnected If necessary power on the device with the button on the fro...

Page 29: ...procedure to connect power to the DC power supply Procedure 1 Locate the ground screw on the back of the chassis Refer to the following figure for the location 2 Attach a 12 AWG ground wire to the cha...

Page 30: ...ns for the 8200TX and 8400TX devices are redundant and hot swappable You can replace an individual fan without powering down the device The TPS TX Series Spare Fan TPNN0266 is a replacement unit and c...

Page 31: ...e the bracket Install the retention bracket The following figure shows the back panel of a TPS 2200T device with the power cord retention bracket installed To install the retention bracket Procedure 1...

Page 32: ...D Use the 32 GB external SSD to store traffic logs snapshots and other system data Only SSDs available from TippingPoint have been validated to achieve optimal performance with TippingPoint products O...

Page 33: ...command erases any existing data on the external user disk user disk mount Manually mounts the external user disk If you replace the external user disk while the device is turned off be sure to also...

Page 34: ...rompted to enter a master key that is between 9 and 32 characters in length contains a combination of numbers and uppercase and lowercase letters and that has at least one special character for exampl...

Reviews: