Pad Assembly Magnetic Holder
61
14.5.3 Pad position setting
The pad position can be set with the pad sliding coupling.
Left / right movement
Untighten clamping screws
B
.
The pad can be moved to the left or right.
The line mark
C
on the ruler indicates the posi-
tion.
Forward / backward movement
Untighten clamping screw
D
.
The pad can be moved forwards or backwards.
All clamping screws must be retightened following
the adjustment of the pad position.
Set limit stop screw
The set tampon position can be fixed in a reprodu-
cible manner with the limit stop screw
E
.
To do this, undo the lock nut and set the screw in
such a manner that its tip touches the pad sliding
coupling. Then retighten the lock nut.
Once the limit stop screw has been correctly set,
the pad coupling can be removed and, when
inserting, can simply be pushed into the guide
until the limit stop is reached.
1
2
3
1
2
3
B
C
1
2
3
1
2
3
D
1
2
3
1
2
3
E
Summary of Contents for MSE 100.1-EU L
Page 1: ...SealCup Express Edition 2 English 2019 02 20 Pad Printer Program version 1 30 30...
Page 4: ...4 Important Information...
Page 18: ...18 Safety instructions...
Page 34: ...34 Transport and Installation...
Page 42: ...42 Pad cleaning...
Page 62: ...62 Pad Assembly Magnetic Holder...
Page 80: ...80 Clich Assembly US...
Page 126: ...126 Manual Mode...
Page 150: ...150 Admin Settings...
Page 160: ...160 Notifications and Errors...
Page 174: ...174 Automation Interface...
Page 176: ...176 Password...