170
Automation Interface
31.6.3 3 Position Fixture
The switching behavior of the inputs and outputs is adapted for a workpiece fixture with
three positions.
Inputs used:
Pin 1 (IN) Prog. IN 1
,
Pin 2 (IN) Prog. IN 2
Outputs used:
Pin 5 (OUT) Prog. OUT 1
,
Pin 6 (OUT) Prog. OUT 2
Pin 8 (OUT) Prog. OUT 3
The inputs and outputs with a HIGH signal are each indicated in the table.
After the START button has been pressed, the following auxiliary function will be carried
out in AUTOMATIC operation mode.
Positions
Step
OUT
IN
START
Move rotary drive to home position.
Activate rotary drive in a clockwise direction.
Position switch signals that position has been reached.
1
1
Move rotary drive to position 2.
Activate rotary drive in a counterclockwise direction.
Position switch signals that position has been reached.
2
2
Press on position 2
Move rotary drive to position 3.
Actively move the limit stop into position.
Activate rotary drive in a clockwise direction.
Position switch signals that position has been reached.
3
1
3
Press on position 3
Move rotary drive to position 2.
Activate rotary drive in a counterclockwise direction.
Position switch signals that position has been reached.
Switch off activation for limit stop (OUT 3).
The limit stop will passively move into position.
2
2
Move rotary drive to position 1.
Activate rotary drive in a clockwise direction.
Position switch signals that position has been reached.
1
1
Press on position 1
END
Summary of Contents for MSE 100.1-EU L
Page 1: ...SealCup Express Edition 2 English 2019 02 20 Pad Printer Program version 1 30 30...
Page 4: ...4 Important Information...
Page 18: ...18 Safety instructions...
Page 34: ...34 Transport and Installation...
Page 42: ...42 Pad cleaning...
Page 62: ...62 Pad Assembly Magnetic Holder...
Page 80: ...80 Clich Assembly US...
Page 126: ...126 Manual Mode...
Page 150: ...150 Admin Settings...
Page 160: ...160 Notifications and Errors...
Page 174: ...174 Automation Interface...
Page 176: ...176 Password...