166
Automation Interface
Pin 17 (IN) START Pad cleaning
The signal has a set switching behavior and cannot be adjusted.
A signal edge from LOW to HIGH starts a pad cleaning cycle. This function is active in
every operation mode.
When a print cycle is being carried out in the AUTOMATIC operation mode the signal is
ignored.
If two-hand operation is used as a safety guard, this signal will not have any function.
See also Chapter
31.8 "Safety guard – two-hand operation" on page 173
.
Pin 18 (IN) Machine ON
The signal has a set switching behavior and cannot be adjusted.
A signal edge from LOW to HIGH switches on the control unit of the machine. For this,
both EMERGENCY STOP circuits (pins 5–6 and 21–22) must be closed.
Pin 19 (OUT) Pad blower
The activation of the output and the desired switching behavior must be set in the menu.
See Chapter
26.7.2 "Pad blower" on page 132
.
Pad blower: a stream of air that is blown onto the pad through a nozzle. This helps to eva-
porate solvents from the ink which has already been absorbed by the pad before printing.
Pin 20 (OUT) Notification cleaning tape
The activation of the output and the desired switching behavior must be set in the menu.
See Chapter
26.7.6 "Sensors cleaning tape" on page 134
.
Depending on the setting the signal will issue a notification for end of tape/torn tape or lack
of tape for the pad cleaning.
Pins 23 und 24 (IN) Movement release
The signals have a set switching behavior and cannot be adjusted.
Two-channel safety signal for the connection of external safety components.
The printer can only carry out movements if the HIGH signal is present at both inputs (23
and 24).
If the LOW signal is present, the movement releases for all drives are safely switched off.
If the machine is integrated in a safety enclosure, the safety switches for the safety doors
can be connected, for example.
If the signals are not used, both inputs must be connected with 24 V DC (pin 15).
Pin 25 (IN) Palm switch
The signal has a set switching behavior and cannot be adjusted.
A signal edge from LOW to HIGH alternately switches the
Pin 12 (OUT) Palm function
output to LOW or HIGH. The status of the output changes with every signal edge.
The function of this input can also be carried out with the foot switch. For this, the function
must be activated in the SETTINGS menu.
See Chapter
26.9 "Foot switch" on page 138
.
Summary of Contents for MSE 100.1-EU L
Page 1: ...SealCup Express Edition 2 English 2019 02 20 Pad Printer Program version 1 30 30...
Page 4: ...4 Important Information...
Page 18: ...18 Safety instructions...
Page 34: ...34 Transport and Installation...
Page 42: ...42 Pad cleaning...
Page 62: ...62 Pad Assembly Magnetic Holder...
Page 80: ...80 Clich Assembly US...
Page 126: ...126 Manual Mode...
Page 150: ...150 Admin Settings...
Page 160: ...160 Notifications and Errors...
Page 174: ...174 Automation Interface...
Page 176: ...176 Password...