Automation Interface
161
31
Automation Interface
31.1
Function
The automation interface can be used to integrate the machine into higher-level control
units.
The signal exchange for notifications and control functions is carried out over this inter-
face. Please contact the manufacturer for the integration of special functions and extensi-
ons.
31.2
Electrical connector
The signal exchange takes place via two D-sub connectors.
(View of the mating face of the female con-
nector.)
25-pole port
Signals to control the functions of the prin-
ter
15-pole port
Signals to control external modules and
functions.
Signals
IN
= input
OUT
= output
HIGH
= 24 V DC (signal switched on)
LOW
= 0 V DC (signal switched off)
Voltage and power rating
Signal
Voltage
Power
Inputs
24 V DC
Outputs
24 V DC
0.5 A
Control voltage (pins 9 & 15)
24 V DC
each max. 0.5 A