Page 5-1
CHAPTER 5: SETUP
5.1
SETUP OVERVIEW
The system setup consists of two setup areas: Supervisor Menu and Setup Menu. The Supervisor
Menu allows configuration of items that customize operation of your scale. The Service Menu
allows configuration of items that are more technical in nature. The Service Menu allows you to re-
calibrate your scale.
5.2
SUPERVISOR MENU
The Supervisor Menu is used to configure the formatting of the information sent to your printer, set
the time & date and enable some of the advanced features.
To access the Supervisor Menu, use the following instructions.
1. Press the * key. The scale prompts for Service Menu or Supervisor Menu.
2. Press the Super soft key. The scale prompts for a password.
3. Key-in the Supervisor Menu password (1234). There is no need to press the ENT key. You are
now in the Supervisor Menu.
5.2.1 CONFIGURATION SUB-MENU (Config)
The Configuration sub-menu is used to enable some of the advanced features and to set
the print format for the time and date. Table 5-1 lists the items which are contained in the
Configuration sub-menu.
Item
Soft Key
Description
Remote Scale Enable/Disable
Remote
Allows you to change the status of the remote scale (if equipped).
The default setting is disabled.
Auto Sampling Enable/Disable
AuSmpl
Allows you to change the status of the auto sampling feature. The
default setting is disabled.
Auto Tare Enable/Disable
AuTare
Allows you to change the status of the auto tare feature. The
default setting is disabled.
Auto Switch Channel
Enable/Disable
AuSw
Allows you to change the status of the auto switch channel
feature. The default setting is disabled.
Target Operation Enable/Disable
Target
Allows you to change the status of the target operation feature.
The default setting is enabled.
lb/kg Conversion Enable/Disable
lb/kg
Allows you to change the status of the lb/kg conversion feature.
The default setting is enabled.
Time Print Format
TmFmt
Let’s you choose the format of the time on the serial printer.
Choices are 12 hour (AM/PM) and 24 hour (military). The default
setting is 12 Hour.
Date Print Format
DatFmt
Let’s you choose the format of the date on the serial printer.
Choices are standard (mm/dd/yy) and international (dd/mm/yy).
The default setting is standard.
Hold Mode Enable/Disable
Hold
Allows you to change the status of the hold feature. The default
setting is disabled.
TABLE 5-1: Configuration Sub-menu Items