Page 4-4
4.3 MEMORY ACCUMULATOR
Your scale comes equipped with a handy memory accumulator, which can be used in conjunction
with the piece counting feature. As with a hand-held calculator, the memory accumulator can be
added to, displayed and cleared at anytime. To access the memory accumulator soft keys, press
the FUNCTIONS key.
NOTE:
This feature can be used when in PCS mode only.
4.3.1 DISPLAYING THE MEMORY ACCUMULATOR
1. Press the MR soft key. The scale briefly displays the total number of pieces,
followed by the total number of entries.
4.3.2 ADDING TO THE MEMORY ACCUMULATOR
1. Press the M+ soft key. The scale adds the current number of pieces to the memory
accumulator, then briefly displays the total number of pieces, followed by the total
number of entries.
4.3.3 CLEARING THE MEMORY ACCUMULATOR
1. Press the MC soft key. The scale asks if you wish to clear the memory accumulator.
2. Press the ENT key to clear the accumulator memory or press the CLR if you do not
wish to clear the accumulator memory.
NOTE:
To exit the memory accumulator function, press the CLR key once.
4.4 USING THE TARGET VALUE
This function works in conjunction with the piece counting feature and allows your scale to act as a
checkweigher. This is useful if you are filling a container with a pre-determined amount of items.
To use, you must enter two values – a lower limit value and an upper limit value. These are
chosen based on the tolerance of your target value. For example, if you wish to fill a bottle with
100 items and you have a tolerance of
±
2 pieces, you would set your lower limit value to 98 and
your upper limit value to 102. The lower and upper limit values may be the same if you have no
tolerance allowance.
If the number of items on the platform is within the two limits, the scale flashes the “Target” soft
and beeps.
NOTE:
This feature can also be used when in weighing mode.
1. Press the FUNCTIONS key.
2. Press the TARGET soft key. The scale prompts for the lower limit value.
3. Use the numeric keys to key-in the lower limit value then press the ENT key. The scale
prompts for the upper limit value.
4. Use the numeric keys to key-in the upper limit value then press the ENT key.
5. Place items on scale until the scale signals that the items are within the entered limits.
NOTE:
To exit the target function, press the CLR key once.