Programmer's Guide
PcOS Series 90PLUS
Printer Control Codes
Graphic Mode
11/07/05
Rev Q
Page 53
There is a configuration option that locks the graphic-save buffer and prevents a new graphic-save
operation from occurring until the lock is manually reset, which inhibits accidental deletion of the
graphic information.
Function
Graphic-save print
ASCII
[ESC] g <0>
Hexadecimal
1BH 67H 00H
Decimal
<27> <103> <0>
IPCL
&%GP
EPOS
[ESC] g <0>
Description
The [ESC] g <0> command prints the graphic-save buffer.
Function
Start graphic-save record
ASCII
[ESC] g <1>
Hexadecimal
1BH 67H 01H
Decimal
<27> <103> <1>
IPCL
&%GS
EPOS
ESC] g <1>
Description
The [ESC] g <1> command clears the graphic-save buffer and starts
recording data. The next 2000 bytes (including characters and commands)
will be recorded.
Function
Stop graphic-save record
ASCII
[ESC] g <2>
Hexadecimal
1BH 67H 02H
Decimal
<27> <103> <2>
IPCL
&%GE
EPOS
[ESC] g <2>
Description
The [ESC] g <2> command stops recording graphic-save information. The
buffer is not saved into nonvolatile memory.
Function
Stop graphic-save record and save
ASCII
[ESC] g <3>
Hexadecimal
1BH 67H 03H
Decimal
<27> <103> <3>
IPCL
&%GW
EPOS
[ESC] g <3>
Description
The [ESC] g <3> command stops recording graphic-save information. The
buffer is saved into the nonvolatile memory.
Note
The printer will remain busy for about seven seconds after the command to
erase and resave the graphic-save buffer into the nonvolatile memory.