Product Self Tests
PcOS Series 90PLUS
Programmer's Guide
Page 126
Rev Q
11/07/05
Recommendation
CTS signal
If active, a false CTS will prevent the printer from sending
any data to the host
Not used
•
Active
DSR signal
If active, a false DSR signal will prevent the printer from
accepting any data.
Not used
•
Active
Multidrop
If set to an address, the multidrop feature will be activated
when the printer is initialized.
Off
•
A device
B device
C device
Off-line
This can be set to active (normal operation) or buffer full
only. In active mode, the printer will go off-line if the cover is
open or the printer runs out of paper. When in buffer full
mode, the printer will only go off-line if a fault is detected.
The buffer full operates normally.
Active
•
Buffer full only
Windows PNP
Microsoft Windows Plug and Play allows Windows to query
the printer as to its identity. The printer supports this in both
parallel and serial modes. This option presets several of the
link modes.
Serial mode
RTS flow control
Parallel mode
IEEE 1284
Off
•
On
Options
Knife
This specifies that the knife option is attached.
Not present
Active
MICR Check
This specifies that the MICR reader option is attached.
Reader
Not present
Active