Operator Panel Controls PcOS Series 90PLUS
Programmer's Guide
Page 112
Rev Q
11/07/05
6
Operator Panel Controls
6.1
Push Buttons - Momentary Switches
The RELEASE key opens and closes the validation clamp. It cycles through three modes: open, closed, and jam
removal. If the RELEASE key is held for two seconds, the slip drive will be activated. Activating the slip drive
is useful for removing jammed slips.
The FEED key advances the receipt and journal paper. If the FEED and RESUME keys are pressed together, the
receipt and journal paper will feed in a reverse direction.
The RESUME key restarts the printer after a validation load failure has been cleared.
6.2
Indicators
There are two indicators. One is READY and the other is FORM (status). The ready indicator is tricolored: red,
green, or orange. The printer can be in any of the following states:
STATE
READY
FORM
Indicator
Indicator
Ready (The printer is ready to receive data and print).
green
off
Printer not ready (Cover is open).
flashing green
off
Ready but waiting for a form
orange
(status)
Request slip form
slow flash
Request validation form
fast flash
Request form be removed
med. flash
Ready but low on receipt paper
flashing orange/green
off
Printer errors
Out of paper
flashing orange
off
Slip load failed
slow flash
Printer fault (See 6.3 Fault Indicators).
flashing red
off
Menu mode
flash orange/green/red
off
Test mode
flash red/orange
off
Printer failure
orange
off
Watchdog fault (printer resets)
Table 19 Printer states