1. PREPARATIONS FOR INTRODUCING THE MACHINE
42
[ 2 ] Selection of cable
②
between inverter and loom
•
These values are calculated on assumption of the supply voltage fluctuation as 5% and voltage drop
by cable as 9%.
•
In an area where supply voltage to the switchboard is unstable, please calculate by setting the voltage
drop by cable separately.
(Unit: mm
2
)
Distance
Power supply voltage
Motor capacity
10 m
20 m
30 m
40 m
50 m
60 m
70 m
80 m
90 m
100 m
200V
1.8 kW
3.5
5.5
8
14
14
22
22
22
30
30
2.6
5.5
8
14
22
22
22
30
30
38
38
3.0
5.5
14
14
22
22
30
38
38
50
50
3.5
5.5
14
22
22
30
30
38
50
50
50
4.0
5.5
14
22
22
30
38
50
50
60
60
5.0
8
14
22
30
38
50
50
60
60
80
220V
1.8 kW
3.5
5.5
8
14
14
14
22
22
22
22
2.6
3.5
8
14
14
22
22
22
30
30
38
3.0
5.5
8
14
22
22
22
30
30
38
38
3.5
5.5
14
14
22
22
30
30
38
38
50
4.0
5.5
14
22
22
30
38
38
50
50
60
5.0
5.5
14
22
22
30
38
50
50
60
60
350V
1.8 kW
3.5
3.5
3.5
3.5
5.5
5.5
8
8
8
14
2.6
3.5
3.5
5.5
5.5
8
8
14
14
14
14
3.0
3.5
3.5
5.5
8
8
14
14
14
14
22
3.5
3.5
3.5
5.5
8
14
14
14
14
22
22
4.0
3.5
5.5
5.5
8
14
14
14
22
22
22
5.0
3.5
5.5
8
14
14
14
22
22
22
30
380V
1.8 kW
3.5
3.5
3.5
3.5
3.5
5.5
5.5
8
8
8
2.6
3.5
3.5
3.5
5.5
5.5
8
8
14
14
14
3.0
3.5
3.5
5.5
5.5
8
8
14
14
14
14
3.5
3.5
3.5
5.5
5.5
8
14
14
14
14
14
4.0
3.5
3.5
5.5
8
14
14
14
14
14
22
5.0
3.5
5.5
8
14
14
14
14
22
22
22
400V
1.8 kW
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
8
8
2.6
3.5
3.5
3.5
5.5
5.5
5.5
8
8
14
14
3.0
3.5
3.5
3.5
5.5
5.5
8
14
14
14
14
3.5
3.5
3.5
5.5
5.5
8
8
14
14
14
14
4.0
3.5
3.5
5.5
5.5
8
14
14
14
14
14
5.0
3.5
3.5
5.5
8
14
14
14
14
22
22
440V
1.8 kW
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
2.6
3.5
3.5
3.5
3.5
5.5
5.5
5.5
8
8
14
3.0
3.5
3.5
3.5
5.5
5.5
5.5
8
8
14
14
3.5
3.5
3.5
3.5
5.5
5.5
8
8
14
14
14
4.0
3.5
3.5
3.5
5.5
8
8
14
14
14
14
5.0
3.5
3.5
5.5
5.5
8
14
14
14
14
14