VENTING CONFIGURATIONS
The power vent is mandatory on
this indoor/outdoor fireplace and
must conform to the following
venting variables:
•
Venting can consist of any
combination of rise and run
up to a total of 110’ includ-
ing up to 3 ft below the unit
and a 66’ vertical rise.
•
Six 90-degree elbows or
combination of other elbows
equaling 90-degrees may be
used.
•
2’ per each 90 degree turn
used must be deducted from
the total allowable venting
length of 110’.
•
Minimum total vent length
is 3 ft plus one 90-degree
elbow.
•
Ensure vent pipe is properly
supported.
Venting Configurations
66’ maximum
vertical rise
110’ maximum
vent length
using power vent
minimum venting - 3’
plus one 90 degree elbow
66’ maximum
vertical rise
Vertical
power vent
Horizontal
power vent
Figure 36: Venting configurations.