100001140
41
TCWS54STOK_270619-56
To connect the lighting wires for the Twilight burner plate, do the following:
• With the control compartment to your left, place the right-hand secondary floor plate in place and route
the two wires from the lights to the left side of the firebox (Figure 88). Feed the two wires down through
the left most grommet in the gas control compartment cover (Figure 89).
• From inside the control compartment, continue to route the wires through one of the electrical knockouts
located in the electrical connection compartment cover (Figure 90).
• For the right hand secondary floor lighting, route the wires through the same grommet and into the
electrical connection box (Figure 91).
• Connect the wires to a switched 120 VAC, 60Hz, 3A power supply, one pair made up of one wire from the
left and one wire from the right light set to the “HOT” incoming line. The remaining pair to the “Neutral”
incoming line (Figure 92).
Wiring instructions for the TC54ST Twilight Burner kit
Figure 88: Right hand plate in place with its wires brought
out from under it.
Grommet
Figure 89: Wires through grommet.
Figure 90: Threading wires through knockout.
Figure 91: Bringing wires through front plate.