![Town & Country Fireplaces D Series Installation Manual Download Page 12](http://html.mh-extra.com/html/town-and-country-fireplaces/d-series/d-series_installation-manual_1141065012.webp)
100001140
Building materials - Outer trim profile view
Siding material - Must
not interfere with outer
door trim removal.
Fireplace outer
wall assembly.
Outer door trim..
1 1/2 inch air space
required from the
bottom of the door
trim for ventilation.
(Facing material or siding
above and/or below the 1 1/2
inch air space, may extend
outwards from the fireplace as
far as desired as long as the
1 1/2 inch air space is maintained).
door frame.
Dashed line indicates
space between removable
window frame and siding
or facing material needed
to allow for removal of
outer door trim
Siding or facing material may
make contact with the door
frame on the top and sides of
the door frame but not with
the bottom of the door
frame. There must be a
minimum 1 1/2 inch space
between the bottom of the
door frame and the siding
to allow for ventilation.
Siding or facing material must
not make contact with the
removable outer window trim.
There must be enough space
between the siding or facing
material and the removable
outer window trim to allow for
removal of door trim.
Location of double side
tape for vapour barrier.
Figure 12: Outdoor-side building materials.
12
TCWS54STOK_270619-56