100001140
For Power Venting this fireplace, “Power Venting Options” on page 17 and “Venting Configurations” on
page 23.
VENT SUPPORTS: A minimum of 1 support every 4’ must be used.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER THAN 1 ½
INCHES FROM ANY PART OF THE VENTING PIPE.
This installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
All electrical installations should be performed by a qualified electrician to the Canadian and U.S. National
Electrical Codes (CSA C22.1 for Canada), (ANSI/NFPA 70 for the U.S.) and/or local electrical codes.
Under no circumstances shall a rheostat be used to alter the voltage supply to this unit.
MINIMUM VENTING CLEARANCES TO COMBUSTIBLE MATERIALS
Terminal casing:
0 in. (0 mm)
Vertical vent pipe:
1.5 in. (38 mm)
Horizontal vent pipe:
1.5 in. (38 mm)
All other clearances are as per the fireplace installation instructions.