tousek
/ E_ST61_07 / 06. 06. 2019
- 5 -
2. Terminal assignment
Swing gate control unit ST 61
supply of photocell transmitter
supply of photocell receiver or accessories, max. 0,3A
common photocell
inner photocell contact
outer photocell contact
capacitator for left motor
capacitator for right motor
grounding
power supply
230V a.c.
flashing light 230V
,
max. 40W
brown
blue or grey
black
green/yellow
brown
blue or grey
black
green/yellow
motor (left leaf)
grounding
motor (right leaf)
grounding
common
ST
OP-button
IMPULSE- switch
common
CLOSE-button
PEDESTRIAN button
common safety edge
safety edge 1 (8,2kOhm)
safety edge 2 (8,2kOhm)
transmitter
rotational speed
sensor signal 1 (left leaf)
rotational speed sensor –
rotational speed
sensor signal 2 (right leaf)
rotational speed sensor –
1
2
3
1
2
3
receiver
30 31 32 30 33 34 50 52 53
20 21 22
23
24 25 26
27
0 1
2
10 11
41 42 43 44 45 46 48
80 81 82 83
Warning
•
Before taking off the control cover,
the main switch must be turned off !
•
The inside of the control unit is under tension when
power supplied.
•
In order to avoid electrical strokes, the safety regula-
tions have to be respected.
•
The device may only be connected by qualified per
-
sonnel (specialised staff).
•
The product is not suitable for installation in explosion-
hazardous/explosive areas.
•
An all-pole disconnecting main switch with a contact
opening gap of min. 3 mm has to be foreseen. The
gate facility has to be secured according to the valid
safety regulations!
•
IMPORTANT: The control lines (sensor, buttons, radio,
photocells, etc.) have to be laid separately from the
230V lines (supply line, motors, signal lamp).
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!