tousek
/ E_ST61_07 / 06. 06. 2019
- 9 -
CLOSE-button
(terminals 30/33)
Buttons/switches
• A command with the CLOSE-switch engages closing of gate. In deadman mode the gate closes as long as the
CLOSE-switch is pressed/switched. As soon as switch is released the gate movement stops.
As CLOSE-buttons you may use pushbuttons or key switches as well as external radio receivers with potential
free make contacts can be used.
STOP-switch
(terminals 30/31)
Buttons / switches
• when pressing the stop switch the gate stops in any desired position.
As stop switch a break contact has to be used.
If no stop switch is connected, terminals 30/31 have to be wire-bridged.
31
30
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!
Push buttons, key switches or external radio receivers with potential-free contacts can be used as pedestrian
button.
Pedestrian button
(terminals 30/34)
Buttons/switches
OPEN/STOP/CLOSE successive impulses:
An impulse of the pedestrian button makes the according gate leaf open/close. If the pedestrian button is actuated
again during this movement, the motor stops. With the next impulse the motor moves in opposite direction of the last
gate movement.
OPEN/CLOSE/OPEN successive impulses:
A command of the pedestrian button makes the according gate wing open/close. If the button is actuated again during
this movement, the travel direction is reversed.
•
In this operation mode it is not possible to stop the motor with the pedestrian button – it always
moves until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
OPEN:
Only opening commands are accepted by the impulse switch – closing the gate with the impulse switch is not
possible.
Impulse OPEN:
The contact at terminals 30/34 works as a second impulse button with the fixed adjustment „OPEN“.
A command with the pedestrian button effects a complete opening of both leaves when the
adjustment “Impulse OPEN” is selected.
DEADMAN:
The motor opens as long as the impulse switch is pressed (hold) – closing the
gate with the impulse switch is not possible. As soon as the switch is released, the motor stops.
If hold to run operating mode is selected, the radio receiver slot (FE) is set out of order for reasons of safety.
The DEADMAN function can not be chosen actively but is set automatically as soon as the impulse
button is set to DEADMAN mode.