Main layer
Sub layer
Adjustments
buttons/switches
page 8, 9
G
impulse button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*) if impulse button is
set to DEADMAN, then
the pedestrian and
close button are also
set automatically to
DEADMAN mode.
(not selectable under
„pedest.- button“)
pedestrian button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
Impulse OPEN
DEAD MAN
*)
safety
page 10–13
G
inner photocell
active
not active
G
outer photocell
active
not active
G
main safety edge 1
active
not active
radio edge TX310
G
main safety edge 2
active
not active
radio edge TX310
photocell function inside
during closing reverse
stop - after release open
during opening stop - then open
photocell function outside
during closing reverse
stop - after release open
PHC-pause time
no influence of photocell
abort pause time
re-start of pause time
immediate close after opening
PHC-self test
active
not active
left leaf
page 16
G
motor
(left)
motor ON
motor OFF
no left operator:
> Motor OFF !
G
delay left leaf
opening delay
closing delay
G
delay time left
0...25s
= 2s
ARS response time
0,15...0,95s
[increment: 0,05]
= 0,50s
max. force
20...100%
= 70%
soft stop time
0...25s
= 5s
soft start
not active
active
only with SWING X !
right leaf
page 16
G
motor
(right)
motor ON
motor OFF
no right operator:
> Motor OFF !
G
delay right leaf
opening delay
closing delay
G
delay time right
0...25s
= 2s
ARS response time
0,15...0,95s
[increment: 0,05 ]
= 0,50s
max. force
20...100%
= 70%
soft stop time
0...25s
= 5s
soft start
not active
active
only with SWING X !
operating mode
page 16, 17
impulse logic
stop, start of pause time
impulse suppression when opening
pause time extension
G
operating mode
impulse mode
automatic 1...255s [increment: 1]
partial opening
25...100%
= 100%
automatic mode
complete/partial opening
only complete opening
only partial opening
pause time logic
no influence
permanent open in automatic mode
closing edges
left/right
inside/outside
limit tolerance
3...20
= 20
lights/lamps
page 18
prewarning OPEN
OFF, 1...30s
= OFF
prewarning CLOSE
OFF, 1...30s
= OFF
courtyard lamp
1
OFF, 5...950
= OFF
control lamp
1
illuminates during open and close
blinks slowly / illuminates / blinks
illuminates in open position
peripherals
page 19–21
electric lock
switched off
1...10s
visible only
if activated under „locking“
reverse stroke
reverse stroke only with active locking!
switched off
0,5...8s
additional module
courtyard/control lamp
status display 1
status display 2
locking
e-lock/magnetic clamp
motor lock
motor lock
OPEN and CLOSE
only OPEN
only CLOSE
visible only
if activated under „locking“
diagnosis
page 22
status display
status display
delete position
NO
YES
factory setting
NO
YES
software version
show software version
serial number
show serial number
1)
The menu points courtyard lamp and control lamp will only appear on display if in menu
„Additional module“
courtyard lamp/control lamp is selected.
Swing gate control unit ST61
+
–
Menu structure
Adjustments - overview
ESC
ENTER
Note: some adjustments regarding function or operating logic can only be executed if gate is closed and if the display shows „r
eady“.