- 20 -
tousek
/ E_ST61_07 / 06. 06. 2019
Optional module for electric lock/magnetic clamp
• The control unit needs an optional module for connec-
tion of an electric lock/magnet (12V or 24Vd.c. version
depending on electric lock).
Connection of module
•
ATTENTION: turn off power supply!
• Fix the module as illustrated in the control with screws at
position
(P1).
• Connect electric lock module via RJ-plug
(E)
with the
control unit
.
• Connect the electric lock (12/24Vd.c.) to the removable
terminals
72/73
of the module.
• The magnet (24Vd.c.) must be connected via a resistor
(R)
for the connection to the module.
• To do this, push the connecting cable of the magnetic clamp
as shown into the opening of the series resistor and fix by
means of crimping pliers.
• Connect the connection cable and resistor
(R)
, as shown,
to the removable terminals
74 (–) / 75 (+)
of the module.
Pay attention to polarity.
• The supply is connected to the 2-pin connector cable
(V)
to the control terminals
(VE)
.
• After wiring, the E-lock-mode has still to be activated in
the menu of the control under LIGHT PERIPHERAL /
ELECTRIC LOCK
• Magnets are driven into the open and closed position of
the gate, the electric lock only in closed position.
P1
E
VE
72 73 74 75
V
– +
electric lock
12 or 24Vd.c
magnet
24Vd.c
R
fix
24V
The series resistor (R) is for tousek
magnets GD 50 and GD 70.
WARNING
: • Before taking off the housing cover the main switch has to be turned off !
• Follow safety instructions!
(
page 5)
optional dropbolt module
• In order to connect the dropbolt SAFELOCK to the control
unit it needs an optional modul and a dropbolt control unit.
If needed then for double leaf swing gate also two dropbolts
can be connected. Thereby the terminal block is labelled
with
„X“
for the first bolt and with
„Y“
for the second bolt.
Modul connection
•
ATTENTION: Turn off the power supply!
• Fix the module inside the control unit´s housing as shown
on the picture. Fix the module on the positions (P1) by
spacers and screws (included).
• Connect the modul to the control unit with RJ-plug con-
nection
(E).
• Carry out the connections on the modul clamps
„X“, „Y“
and on the motor control unit clamps as shown on the
picture.
• After succesful connection the dropbolt operation need to
be activated in the control unit menu („peripherials/locking“
and „peripherials/dropbolt“)
ST 61 with integrated dropbolt modul
IMPORTANT: When using only one drop bolt, the wire jumper must remain in the unused terminal block!
E